Quality Finishes That Last a Lifetime
Pack Sizes
-
4 Ltrs 10 Ltrs and 20 Ltrs
Surface Preparation
Ensure that the surface to be coated is clean and free from oil, grease ,dirt and other contamination
Clean thoroughly using a wire brush and then scuff the surface using#SandPaper 80. Ensure that no loose particles are sticking to the surface to be coated
Freshly plastered surface must be allowed to cure completely. The coating process can be started after a minimum period of 30 days
Do not apply if the surface is damp or when the humidity high
Completely remove existing coating, if any to ensure direct adhesion of TeraFix to the surface
Damaged surface should be rectified before applicationof TeraFix
Apply Using
Brush or Roller
Thinning Details
-
Thinner Recommended - 555 Thinner
Thinner Intake | 5% |
Application Procedure
Mix the base thoroughly prior to application.
Ensure that the surface to be coated is clean and free from oil, grease , dirt and other contamination
Clean thoroughly using a wire brush and then scuff the surface using # Sandpaper 80. Ensure that no loose particles are sticking to the surface to be coated.
Apply one of TERAFIX for regular terrace surfaces . For uneven / highly porous surfaces apply 2 coats of TERAFIX with an interval of 6 - 8 hours between each coat. Sanding of the first coat shall be done using # 220 Sandpaper.
Apply 2 coats of Aquafresh Cool with an interval of 4 to 5 hours between subsequent coats after subjecting TERAFIX to sanding using # 220 Sandpaper.
After completion, allow curing for a minimum period of 72 hrs
Pack Sizes
-
1 Ltr,4 Ltrs,10 Ltrs and 20 Ltrs
Features
-
5 - Best in Class
-
4 - Very Good
-
3 - Good
-
2 - Average
-
1 - Poor
- Lead Content - Less than 90 PPM
- Temperature reduction : 5 - 12 ?C depending on the surface temperature *
- * The drop in temperature varies with the temperature of the surroundings, higher the temperature, greater will be the reduction.
- The reduction in temperature is influenced by the wear and tear , the surface of the film undergoes with time.
Surface Preparation
The surface to be coated should be clean, free from dampness and any other contamination.
Clean the surface thoroughly using a wire brush and then sand the surface using # 80 Sandpaper
Clean thoroughly and ensure that no loose particles are sticking to the surface to be coated.
For freshly plastered surfaces , painting can be initiated after a minimum period of 30 days.
Thinning Details
Potable water | 35 - 40% |
Application Procedure
Mix the base thoroughly prior to application.
Apply one coat of Aquafresh Primer. After 3 to 4 hrs, mild scuffing of Primer should be done with # 400 Sandpaper.
Apply 2 coats of Aquafresh Cool with an interval of 4 to 5 hours between subsequent coats.
After completion, the coating should be allowed to cure for a minimum period of 72 hrs
Pack Sizes
-
1 Ltr, 4 Ltrs and 20 Ltrs
Surface Preparation
Clean using Thinner for finish or appropriate cleaning agent and apply the desired Glasscoat Finish as per recommendation
Thinning Details
-
Thinner Recommended - Thinner for finish
GlassCoat Finishes | 15 - 20% |
Application Procedure
Mix the base thoroughly prior to mixing with the hardener
Avoid applying in direct sunlight or when the humidity is very high
For application details, please refer product data sheet in downloads menu
Pack Sizes
-
1 Ltr, 4 Ltrs and 20 Ltrs
Surface Preparation
The tile to be coated should be clean, dry, free from moisture ,dampness and other contamination.
Sand the surface using Emery Paper No. 80 and clean thoroughly so that no loose particles are held to the surface.
Tilegarde - Solvent Based Coat for Porous Roof Tiles - Paint for Roof Tiles | MRF Paints
Tilegarde Paint for Roof - Single Pack Solvent Based Coat for Porous Roof Tiles comes in 1 Ltr, 4 Ltrs and 20 Ltrs pack.
Thinner Recommended
GP Thinner | 5 - 10% |
Application Procedure
Mix the base thoroughly prior to application. Apply two coats of the desired TileGarde shade / Tile Garde Clear with an interval of 8 hrs between the subsequent coats. Mild sanding of the first coat with Emery paper No. 400 is required before the application of the second coat. Do not apply when the humidity is very high.
Pack Sizes
-
500 ml,1 Ltr,4 Ltrs and 20 Ltrs
Surface Preparation
Mix the base (Part A) thoroughly before the addition of hardener (Part B). Ensure that the hardeneris slowly added to the base in the specified ratio.
Add the recommended thinner after thoroughly mixing the base and hardener. The mixture should be used within its pot life. Ensure a dust free environment during application
Thinning Details
-
Mix the base thoroughly prior to mixing with the hardener
Thinner Recommended
Epoxy Zinc Phosphate Primer Grey/ Dark Grey | Thinner 1110 Ep |
GMP Epoxy Red Oxide Red | Thinner 1110 Ep |
Epoxy Primer Oxide Red/ Metal Grey/ Surfacer Grey | Thinner 1110 Ep |
Epidec Epoxy RTC Primer Grey/ Zinc ph primer Grey | Thinner 1110 Ep |
Thinner Intake
Epoxy Zinc Phosphate Primer Grey | 30 - 35% |
Epoxy Zinc Phosphate Primer Dark Grey | 15 - 20% |
GMP Epoxy Red Oxide Red | 15 - 20% |
Epoxy Primer Oxide Red/ Metal Grey/ Surfacer Grey | 15 - 20% |
Epidec Epoxy RTC Primer Grey | 3 - 5% |
Epidec Epoxy Zinc ph primer Grey | 15 - 20% |
Epoxy putty - white / Grey | 3 - 5% |
Epidec Epoxy Matt | 10 - 15% |
Epidec Epoxy Glossy | 15 - 20% |
MRF Coal Tar Epoxy | 15 - 20% |
Epidec Epoxy ROC Black | 3 - 5% |
Application Procedure